Spectrascan® Spectroradiometer

PR-730/735

The PR-730 uses 512 detectors to sample the emitted spectrum from 380 to 780 nm yielding a resolution of 0.781 nm/pixel. Data is reported every 1 nm.The spectral range of the PR-735 is 380 to 1080 nm for a resolution of 1.348 nm/pixel and 2nm increments.Ease of navigation through menus, and vivid information screens including a full color spectrum, is supplied by the high-resolution color touch screen display. Up to 8 measuring apertures can be supplied on the instrument providing unequaled spot size /sensitivity versatility.The capability to synchronize measurements (AutoSync) to the frequency of the display backlight or source refresh ratehelps insure repeatable results.

Brochure Download: 

An external trigger circuit lets you make precise measurements of flashing sources such as xenon strobes. The PR-730 can measure as low as 0.0001 (000005 for the PR-735) footlamberts (0.0003 or 000015 cd/m'). Accurate measurements of polarized sources like LCD's is guaranteed by the extremely low polarization characteristics (<0.2%). The PR-730 has variable bandwidth capability - select between 2, 5, 8 nm spectral bandwidths to insure the optimum conditions for virtually any sample.

Easy to Use

The high resolution, full color touch screen display provides both an easy means of negotiating through instrument setup menus and of viewing measured results, including a full-color Spectral Power Distribution (SPD) graph of the measured sample.

Connectivity

A wide selection of interfacing options, USB, RS232 and Bluetooth wireless, adds convenience and ease when communicating with and controlling the PR-73ol7 35. With the Bluetooth option, the instrument will communicate for up to 100 feet (305 m) away from the base - ideal for situations where cabling is not possible.

Variable Spectral Bandwidth

The PR-730 and PR-735 introduces a new feature to the SpectraScan line - variable spectral bandwidth. One of 3 bandwidth settings (2. 5 or 8 nm) can be selected regardless of the measuring aperture being used. This lets the user change the bandwidth without changing apertures – or instruments.

Versatility

The PR-730/7 35 provides unsurpassed flexibility with the world's largest selection of optical accessories. It is the only instrument in its class that can measure radiance/luminance, irradiance/illuminance, radiant flux/lumens and radiant intensity/candelas simply by changing accessories.

Control

Remote Mode software makes it possible to control the PR-730/735 from a custom application as easy as sending and receiving text characters over any of the available interfaces. SpectraWin 2 is a full Windows based executable that makes measurements, graphically displays results and has powerful data manipulation capabilities.

An RGB Display Cal Module can be added to SpectraWin that provides an interactive interface that helps automate the process of calibrating displays or digital projectors.

User Self Calibration Software is available if you wish to calibrate your instrument in-house. It can be a great time and money saver especially when several instruments are involved.

PRITCHARD 730/735

Aerospace

Aerospace displays, regardless of the model, present a unique challenge in that required capabilities range from very low (0.1 fl ) to very high (10,000 fc) photometric levels of small areas. The PR-730/735 meets these challenges by providing multiple apertures, variable bandwidth and excellent sensitivity

Computer Displays / TV's

Photo Research SpectraScans have been providing solutions to the computer display and TV markets for decades. The PR-730/735 now makes it possible to easily address one of the toughest tasks, spectral contrast measurements, without having to relay on a second instrument.

Components

The PR-730/735 is not just a luminance meter. It's wide range of accessories can address virtually any light measurement application. For example, the LR-127 LED Analyzer is designed to measure discrete LED's for conformity to the CIE 127 Technical Report - Measurement of LED's.
Wavelength Range PR-730 : 380 nm - 780 nm
PR-735 : 380 nm - 1080 nm
Detectors 512 Cooled Detectors
Spectral Bandwidth 3 Option 1 PR-730 : 3, 5 or 8 nm
PR-735 : 5, 9 or 14 nm
Option 2 : Switchable PR-730 : 2, 4 and 8 nm
PR-735 : 4, 8 and 14 nm
Wavelength Accuracy PR-730 : < 0.4 nm
PR-735 : < 0.8 nm
Spectral Resolution PR-730 : 1nm
PR-735 : 2nm
Digital Resolution 16 bits
Available Measuring Apertures

(Select up to 8 per instrument)
2°, 1°, 1/2°, 1/4°, 1/8°, 0.2°, 0.1°,

0.1° x 1° (Hor . Slit),

0.1° x 2° (Ver. Slit),

0.5° x 1.5° (Hor. Slit)
Standard Lens MS-75 - 75 mm
Luminance Sensitivity for Illuminant A (2856K) 1 2 0.0001 fL (0.0003 cd/m²) with 2° aperture
Luminance accuracy 1 2 ±2% against NIST traceable Illuminant A standard at 0.003 fL (0.009 cd/m²) with 2° aperture
Luminance repeatability 1 2 =1%  at 0.0031 fL (0.009 cd/m²) with 2° aperture against NIST traceable Luminance Standard at 2856K (Illuminant A)
Color Accuracy 1 2 ±0.0015 for CIE 1931 x, y for Illuminant A (2856K) at 0.003 fL (0.009 cd/m²) with 2° aperture
Color Repeatability 1 2 0.0005 for CIE 1931 x, y for  Illuminant A (2856K) at 0.003 fL (0.009 cd/m²) with 2° aperture
Polarization Error <0.2%
Stray Light <0.06%
Storage Secure Digital (SD) Card
AutoSync Range 20 to 2000 Hz.
Interfaces USB, Bluetooth, RS232
Power Requirements Rechargeable Li-ion battery or AC Adapter (90 - 240 VAC)
Battery Life > 8 hours
Weight 14.25 lbs. (6.46 kg)
Dimensions 11.03  in. L x 6.69 in. W x 8.0 in. H

(28.0 cm x 17.0 cm x 20.3 cm)
Operating Temperature 34° to 95° F (1° to 35° C)
Humidity 0 - 90% non-condensing

1 - Luminance values are for the PR-730 with 8 nm bandwidth. For the PR-735, divide luminance values by 2.0.
2 - Luminance values are with the 8 nm bandwidth
3 - For the PR-735, multiply bandwidth values by 2
Note:

All specifications are subject to change without notice.

Aperture vs. Measurement Spot Size

Aperture
Accessory Working Distance 0.5° 0.25° 0.1°
MS-75

(355 mm to infinity)
355 mm



305 m
10.5 mm



10.64 m
5.25 mm



5.32 m
2.63 mm



2.66 m
1.315 mm



1.33 m
0.525 mm



532 mm
SL-0.5x 94.1 mm

to

137 mm
3.0 mm

to

5.08 mm
1.5 mm

to

2.54 mm
0.75 mm

to

1.27 mm
0.375 mm

to

0.635 mm
0.15 mm

to

0.254 mm
SL-1x 46 mm

to

66 mm
1.78 mm

to

2.64 mm
0.890 mm

to

1.32 mm
0.445 mm

to

0.660 mm
0.226 mm

to

0.330 mm
0.089 mm

to

0.132 mm
MS-7.5 100.0 mm



30.5 m
35.0 mm



10.64 m
17.5 mm



5.32 m
8.75 mm



2.66 m
4.38 mm



1.33 m
1.75 mm 



532 mm
LA-730 Contact 13.2 mm 13.2 mm 13.2 mm 13.2 mm 13.2 mm
FP-730 Contact 3.17 mm 3.17 mm 3.17 mm 3.17 mm 3.17 mm


Luminance Sensitivity (fL) †

Aperture
Accessory Units 0.5° 0.250° 0.10°
MS-75 fL 0.0001 0.0004 0.0016 0.0064 0.041
cd/m² 0.00034 0.0014 0.0055 0.022 0.14
SL-0.5x fL 0.0001 0.0004 0.0016 0.0064 0.041
cd/m² 0.00034 0.0014 0.0055 0.022 0.14
SL-1x fL 0.0001 0.0004 0.0016 0.0064 0.041
cd/m² 0.00034 0.0014 0.0055 0.022 0.14
MS-7.5 fL 0.0001 0.0004 0.0016 0.0064 0.041
cd/m² 0.00034 0.0014 0.0055 0.022 0.14
LA-730 fL 0.0001 0.0004 0.0016 0.0064 0.041
cd/m² 0.00034 0.0014 0.0055 0.022 0.14
FP-730 fL 0.00025 0.001 0.004 0.016 0.10
cd/m² 0.0009 0.0034 0.0137 0.055 0.34
CR-730 fc 0.0002 0.0008 0.0032 0.0128 0.08
lux 0.002 0.008 0.032 0.128 0.80


† Stated sensitivities are for a precision of 10:1 against an Illuminant A (2856 K) source
Note:

All specifications are subject to change without notice.
6730-0002-00 SW-730 - SpectraWin™ 2 Lite Operating Software
Full featured, menu driven, Windows software. Calculates luminance, CIE chromaticity, correlated color temperature, dominant wavelength and excitation purity from measured spectral data. Provides features such as graphically represented spectral distribution and CIE color space (1931 and 1976), data manipulation (math functions) save/recall binary or ASCII files, print graphics screens or tabular data, reflectance/ transmittance L*a*b*u*v* measurements, ?E Color Difference and Color Rendering Indices (CRI) of lamp sources. Operates under Windows XP. (Windows XP Professional recommended).

All software is serialized to an instrument. One licensed copy needs to be purchase per instrument.
6730-0002-01 SW-730-P - SpectraWin™ 2 Pro Operating Software
Includes all of the capabilities of SpectraWin™ 2 Lite and also features a Macro Option allowing the end user to create macros that can generate automated test sequences.

All software is serialized to an instrument. One licensed copy needs to be purchase per instrument.
6730-0002-07 SpectraWin Lite to Pro Upgrade
6730-0002-02 SpectraWin™ 2 RGB DisplayCal Module
Optional module in SpectraWin™ 2 Lite or Pro designed for spectrally based white point calibrations of CRT's, LCD's, PDP's and digital projectors. Calibration is based on "learned" RGB values or user entered Y, xy, CCT values. Calibration is facilitated by on-screen graphical feedback of an RGB bar graph or a moving color point within a CIE diagram. Must be purchase with SpectraWin™ 2.

All software is serialized to an instrument. One licensed copy needs to be purchase per instrument.
6730-0002-03 PR-730/735 SDK (.DLL)
Fully documented API for measurement, control and data transfer from the PR-730/735. Includes C++ and Visual Basic sample code and SpectraWin™ 2 Lite software. Compatible with Windows XP operating system or higher.

One licensed copy per instrument must be purchased.
6730-0002-04 USC-730 - User Self-Calibration Software
Provides complete recalibration capabilities for the PR-730/735 including wavelength accuracy, spectral intensity and linearity. Requires helium (e.g. WC-100) or mercury-argon (e.g. WC-715/735) wavelength calibration source and variable spectral radiance/luminance standard (e.g. LRS-455). This package provides that ability to calibrate one instrument aperture.

All software is serialized to an instrument.

One licensed copy needs to be purchase per instrument. Consult the PROML Price List for more information regarding sources.
6730-0002-08 USC-730 - Aperture Module Software
This software module is required to calibrate additional apertures (multiple aperture instruments). One module is required for each additional aperture (i.e. a three aperture instrument requires two modules). All software is serialized to an instrument.

One licensed copy needs to be purchase per instrument.

See USC-730 User-Self Calibration Software

*Requires Calibration with Instrument

6730-0001-00 PR 730 - SpectraScan SpectroRadiometer (North American Plug)
 
 
The PR-730 is the latest addition to the SpectraScan line and it is a portable, stand-alone instrument.It is a simultaneous acquisition spot spectroradiometer for spectroradiometric and photometric measurements in the lab or on the production floor.Spectral measurements are made from 380 to 780 nm at 1 nm increments. The bandwidth of the system is 8 nm. The PR-730 has a multiple aperture wheel and can be provided with 1 to 8 apertures. At least one aperture needs to be added from the aperture list on the next page.
The Standard PR-730 System includes:
PR-730 SpectraScan
MS-75 Lens
Must add at least one Aperture (Maximum 8)
AutoSync®
Secure Digital (SD) Card
External Trigger Port (Trigger Cable Not Included - See Connectivity Accessories)
BP-730, Li-Ion Rechargeable Battery
AC-730-6, A/C Adapter(6 ft.) with North American AC cord
CD with drivers and Instruction Manual
NIST Traceable calibration (certified for 1 year)
 
6730-1001-00 PR-730 - SpectraScan (Continental Europe Plug)
 
   
 
6730-2001-01 PR-730 - SpectraScan (U.K./Ireland/Hong Kong/Singapore Plug)
 
   
 
6730-3001-02 PR-730 - SpectraScan (Australia / New Zealand Plug)
 
   
 
6735-0001-00 PR 735 - Extended Range SpectroRadiometer (North American Plug)
 
  Same as the PR 730 with spectroradiometry from 380 - 1080 nm at 2 nm increments. Must add one aperture (Maximum 8)
 
6735-1001-00 PR-735 - SpectraScan (Continental Europe Plug)
 
   
 
6735-2001-01 PR-735 - SpectraScan (U.K./Ireland/Hong Kong/Singapore Plug)
 
   
 
6735-3001-01 PR-730 - SpectraScan (Australia, New Zealand Plug)
 
6730-0004-00 2° Round Aperture
 
6730-0004-01 1° Round Aperture
 
6730-0004-02 0.5° Round Aperture
 
6730-0004-03 0.250° Round Aperture
 
6730-0004-04 0.2° Round Aperture
 
6730-0004-05 0.125° Round Aperture
 
6730-0004-06 0.1° Round Aperture
 
6730-0004-07 0.1° x 1° Horizontal Slit Aperture
 
6730-0004-08 0.5° x 1.5° Horizontal Slit Aperture
 
6730-0004-09 0.1° x 2° Vertical Slit Aperture
 
6730-0003-00 VBW-730 Variable Bandwidth Option
 
  With this option, the user can change the bandwidth between 2, 4 and 8 nm for the PR-730 and 4, 8 and 14 nm for the PR-735. This option is a must when it is necessary to enhance resolution when measuring sources that emit narrow spectral signatures such as LED's.
 
6730-0003-01 BT-730 Bluetooth
 
  Provides a wireless interface between a Bluetooth enabled host computer and the PR-730/735.
 
6730-0003-03 RS-232 Port
 
  Adds a port to connect to RS-232 devices. Includes a 3 meter cable terminated on one end with a 9 pin sub-D female connector.
 
6730-0003-02 TG-OPT - External Trigger Option
 
  Used to externally trigger a PR-730 / 735 measurement and to simultaneously send a pulse to a remote device such as a strobe light.
 
6730-0009-02 BP-730 - Li-ion Rechargeable Battery (Internal)
 
  Lithium-ion battery for the PR-730 integrated in the instrument. 8 hours of continuous use with a full charge.
 
6730-0003-12 CIE Color Chart
 
Displays full color CIE 1931 Chromaticity Diagram with measured point following a measurement on the instrument.
 
6730-0003-09 CIE Pass / Fail
 
Create regions in the CIE 1931 chromaticity diagram that act as Pass / Fail criteria. If the measured color falls in the specified region, Pass is reported on the instrument display or Fail if the measured point falls outside the region. The measured point and region are also displayed on a color 1931 CIE diagram. Regions can be defined as squares, rectangles, polygons (3 - 10 sides), circles or ellipses. When not enabled, a full color CIE 1931 Chromaticity Diagram with measured point is displayed.
 
6730-0003-10 Color Rendering Index (CRI)
 
Calculate all 14 CRI indices and the average CRI (using indices 1 - 8). User selectable or automatically generated reference. CCT and chromaticity tolerances are also set by the operator. Results are reported on the instrument display.

*Requires Calibration with Instrument

Luminance Accessories

6730-0008-15* MS-75 - MacroSpectar® Lens
C mount lens focusable from 14" (0.25X magnification) to infinity. See Measurement Spot Size & Luminance Range for focus distance and field coverage (spot size) information. This is the Standard Objective Lens for the PR 730 and PR-735.
6730-0008-16* SL-0.5x - Supplementary Lens
0.5X magnification lens that provides a field coverage halfway between the MS-75 and SL-1X lenses. See Measurement Spot Size & Luminance Range for focus distance and field coverage (spot size) information. Threads into the MS-75 during use.
6730-0008-17* SL-1x - Supplementary Lens
1X magnification, fixed focus lens for luminance/radiance measurements. Threads into the MS 75 lens during use. See Measurement Spot Size & Luminance Range for focus distance and field coverage (spot size) information.
6730-0008-20* MS-7.5 mm - MacroSpectar® Wide-Field Lens
C mount lens with a 3.94" minimum working distance (0.025X magnification) to infinity. See Measurement Spot Size & Luminance Range for focus distance and field coverage (spot size) information. This lens is suitable for large area coverage at short distance for non-contact color quality control (L*a*b*) measurements.

*Requires Calibration with Instrument

Miscellaneous Luminance Accessories

6730-0008-12* FP-730 - 2 Foot Flexible Probe
2 foot (60.9 cm) long probe designed for contact measurements of luminance and radiance. Probe tip is 0.125" (3.18 mm) diameter. Replaces the MS-75 during use..
6730-0008-27* FP-730 - 4 Foot Flexible Probe
4 foot (121.9 cm) long probe designed for contact measurements of luminance and radiance. Probe tip is 0.125" (3.18 mm) diameter. Replaces the MS-75 during use.
6730-0008-28* FP-730 - 10 Foot Flexible Probe
10 foot (3.05 m) long probe designed for contact measurements of luminance and radiance. Probe tip is 0.125" (3.18 mm) diameter. Replaces the MS-75 during use.
6730-0008-09* LA-730 - Luminance Adapter
Contact measurements for luminance and radiance are performed with this adapter which covers 0.52" (13.2 mm). Replaces the MS-75 during use.

*Requires Calibration with Instrument

Illuminance Accessories

6730-0008-10* CR-730 - Cosine Receptor
For cosine corrected illuminance/irradiance measurements. Replaces the MS-75 lens during use.
6730-0008-08* ICC-730 - Integrating Cosine Corrector
This 3" (76.2 mm) integrating sphere features a 1 inch (25.4 mm) entrance port and is designed for applications where the integrated measurements of point sources is required. The sphere is fully baffled to insure complete integration of the incoming radiant energy. Calibrated for spectral Irradiance (watts /meter²) and reports Illuminance (footcandles and lux), chromaticity coordinates and correlated color temperature.

*Requires Calibration with Instrument

Luminous Flux Accessories

6730-0008-07* IS-730 - Integrating Sphere
This 3" (76.2 mm) integrating sphere is designed to measure small point sources (e.g. miniature lamps, LED's, etc.) over 4p steradians. Calibrated for spectral Radiant Flux (watts) and calculates Luminous Flux (lumens), color temperature and chromaticity coordinates. Accepts 0.125" (3.18mm) and 0.250" (6.36mm) sources and replaces the MS-75 during use.

Consult factory for other special sizes.

*Requires Calibration with Instrument

Luminous Intensity Accessories

6730-0008-13* LR-730 - LED Receptor
Designed to measure discrete LED's, the accessory accepts 0.125" (3.18 mm) diameter and 0.25" (6.36 mm) diameter LED's. Calibrated for radiant intensity (µw * sr-1) and luminous intensity (millicandela) with an 8° acceptance angle. Replaces the MS-55 during use.

Consult factory for alternate LED diameters.
6730-0008-14* LR-127 - CIE 127 - LED Analyzer
This patented optical accessory is designed to test discrete LED's for compliance to CIE 127. Tests both conditions A (far) and B (near) of the CIE recommendation. Calibrated for luminous intensity (millicandelas). Both conditions can be tested with the flip of a lever from 'A' to 'B'. No need to change tubes or even remove the LED between tests. Accepts T1 (3 mm) and T1.75 (5 mm) packages. Replaces the MS-55 during use.

Consult factory for alternate LED packages.

*Requires Calibration with Instrument

Filters

6730-0008-21* CEF-735 - Color Enhancement Filter
2" x 2" (50.8 x 50.8 mm) external filter that suppresses radiation above approximately 780 nm. Used with the PR-735 only for colorimetry applications. Requires the FH-735.
6730-0008-22 CRF-35 - Chromaticity Reference Filters
SSet of 20 2"x2" (50.8 x 50.8 mm) filters used for chromaticity accuracy checks. Requires the FH-730.

Includes calibration data.
6730-0008-00* ND-730-0.3 - Neutral Density Filter - ND-0.3
This ND filter attenuates the signal by approximately 2 times (50% transmission). The ND-730-0.3 can be mounted on either the MS-75 or SL-1X lenses.
6730-0008-01* ND-730-0.7 - Neutral Density Filter - ND-0.7
This ND filter attenuates the signal by approximately 5 times (20% transmission). The ND-730-0.7 can be mounted on either the MS-75 or SL-1X lenses.
6730-0008-02* ND-730-1 - Neutral Density Filter - ND-1
This ND filter attenuates the signal by approximately 10 times (10% transmission). The ND-730-1 can be mounted on either the MS-75 or SL-1X lenses.
6730-0008-03* ND-730-2 - Neutral Density Filter - ND-2
This ND filter attenuates the signal by approximately 100 times (1% transmission). The ND-730-2 can be mounted on either the MS-75 or SL-1X lenses.
6730-0008-04* ND-730-3 - Neutral Density Filter - ND-3
This ND filter attenuates the signal by approximately 1000 times (0.1% transmission). The ND-730-3 can be mounted on either the MS-75 or SL-1X lenses.
6730-0008-29* ND-730-4 - Neutral Density Filter - ND-4
This ND filter attenuates the signal by approximately 10,000 times (0.01% transmission). The ND-730-4 can be mounted on either the MS-75 or SL-1X lenses.
6730-0008-11 FH-730 - Filter Holder
Designed to hold two 2" x 2" (51 mm x 51 mm) filters. Ideal for filter transmission measurements. Threads into the MS-75 or SL-1X lenses.

*Requires Calibration with Instrument

Reflectance Standards

6730-0008-05* RS-3 - Reflectance Standard
2" diameter (51 mm diameter) PTFE reflectance standard used for making ambient light measurements, measurements of point sources (e.g. lamps) or measurements of the illuminating source for reflectance or L*a*b* calculations. The RS-3 is uncalibrated, meaning that all spectral reflectance correction factors are set to 1.00. SAE ¼ - 20 thread, black anodized, aluminum case.
6730-0008-06* SRS-3 - Spectrally Calibrated Reflectance Standard
All the capabilities of the RS-3 and calibrated for absolute spectral reflectance @ 45. Includes reflectance factors and certificate of calibration.

*Requires Calibration with Instrument

Connectivity Accessories

6730-0009-08 TG-10 - 10 ft (3.05 m) Trigger Cable
Used for externally triggering a PR-730 measurement, and to simultaneously send a pulse to a remote device such as a strobe lamp. 10 foot cable terminated with a 6 pin mini-DIN connector.
6730-0009-09 USB-3 - 3 ft (0.91 m) USB Interconnecting Cable
6730-0009-10 USB-10 - 10 ft (3.05 m) USB Interconnecting Cable
6730-0009-11 GPIB-USB Interface
Converts USB to GPIB (IEEE-488) protocol.

Interface cable not included
6730-0009-18 BTA-730 - Blue Tooth Adapter
Class 1 extended range (up to 100 meters) USB Blue Tooth adapter for the host computer and Photo Research device driver. Works well with SpectraWin™ 2 and Remote Mode.
6730-0009-21 RS232 (DB9F) to RJ-12 Connector
Interconnector for RS232 Cable from PR-730 to PC.
6730-0009-22 RS232 Cable - 6 Meter
6 meter RS232 cable terminated at both ends with RJ-12 connectors.
6730-0009-23 RS232 Cable - 10 Meter
10 meter RS232 cable terminated at both ends with RJ-12 connectors.
6730-0009-19 USB-15 - 15 ft. (4.57 m) USB Cable
6730-0009-20 USB-EXT - 16 ft. (4.88 m) USB Extension Cable
USB active extension cable. A maximum of 4 cables can be used. Requires 6730-0009-19 standard 15 ft. cable be purchased.

System Power Accessories

6730-0009-00 AC-730-6 AC Adapter with 6 foot Cord (Standard with the PR-730)
(with 117 VAC North American Power Cord). 90 - 240 VAC input.
6730-0009-01 AC-730-20 AC Adapter with 25 foot Cord
(with 117 VAC North American Power Cord). 90 - 240 VAC input.
6730-0009-02 BP-730 - Li-Ion Rechargeable Battery (Internal)
Lithium-Ion battery for the PR-730 integrated in the instrument. 8 hours of continuous with a full charge.

Data Storage Accessories

6730-0009-04 SD - Secure Digital Card
6730-0009-05 SD-R - USB SD Card Reader
For use when transferring measurement data from the PR-730 to a PC. USB cable not included.

Miscellaneous Accessories

6730-0009-12 CK-730 - Integrated Color Camera Kit (Color Camera, No Monitor)
This kit provides a means of remotely viewing the measurement scene through the eyepiece of the PR-730. Includes an adapter for mounting the camera on the eyepiece and camera power supply. The camera output format is NTSC.
6730-0009-13 CKM-730 - Integrated Color Camera Kit (With Monitor)
This kit provides a means of remotely viewing the measurement scene through the eyepiece of the PR-730. Includes an adapter for mounting the camera on the eyepiece, camera power supply and color monitor.
6730-0009-14 CC-730 - Molded Carrying Case
Fiberglass carrying case with molded foam inserts offering maximum protection for the PR-730 and accessories.
6730-0009-16 TR-15 - Tripod
Fully adjustable tripod with SAE ¼-20 screw mount for stable measurements with the SpectraScan when an optical table or bench is not available.