The PR-650 SpectraColorimeter is the latest in the Photo Research family of SpectraScan
fast scanning instruments. It's the only truly portable, spectrally-based
luminance telephotometer/colorimeter. Complete, NIST-traceable photometric and colorimetric
measurements are performed spectroradiometrically. And, this hand-held portable
overcomes the spectral errors inherent in filter instruments.
|
|
|
The right instrument
|
|
When battery-powered portability, ease-of-use, connectability and spectrally accurate
measurement results are important criteria when selecting a photometer or colorimeter,
the PR-650 SpectraScan is the instrument of choice.
|
|

|
|
Battery powered portability
|
|
The PR-650 is the only truly portable spot spectroradiometer available. The standard
NiCad battery makes the PR-650 ideal for making measurements in remote areas where
an AC power source is unavailable. Combine this portability with a laptop running
the optional SpectraWin™ Windows®
based software, and you have a full-featured measurement system that can be transported
in your briefcase.
|
|

|
|
Ease of use
|
|
The PR-650 is as easy to use as point-and-shoot. The world famous Pritchard®
optics make target alignment as easy as aim/focus/shoot. When you are ready to make
a measurement, simply press the measure button. The results are displayed on the
backlit 4 x 20 character LCD display.
|
|

|
|
Connectability
|
|
Each PR-650 is equipped with an RS-232 cable that lets you link to the outside world
from just about any platform (PC, Mac, Sun Workstation etc.). We've also included,
as standard equipment, Remote Mode control language. This simple to use text based
language lets you make measurements with the PR-650 and retrieve calculated measurement
results - all from your custom software application (e.g. Visual C++, Visual Basic
etc).
|
|

|
|
SpectraWin™ software
|
|
For an easy-to-use, graphics based link to the PR-650, the optional Windows®
('98, 2000 or XP) SpectraWin™ software
package provides a fully functional control, display and calculation platform. Features
such as automated measurement sequences (reflectance, transmittance etc.), go/no
go color measurements and a built in macro recorder make your measurement task as
easy as click and go. After the measurement, cut-and-paste data tables or graphics
displays (e.g. spectral or CIE charts) to other Windows applications.
|
|

|
|
Spectral Accuracy
|
|
Unlike other instruments in its price range, the PR-650 measures optical radiation
spectrally instead of relying on filter technology. To accurately deliver important
measurement results such as luminance and chromaticity - the PR-650 determines these
parameters by measuring the absolute intensity at each wavelength, then calculating
the appropriate CIE value. So, regardless of the source, the result is accuracy
time after time after time.
|
|

|
|
AutoSync®
|
|
The built-in AutoSync® feature takes the worry out of accurately measuring
high intensity refreshing sources such as CRT's by adjusting the exposure time to
the source refresh rate - and simultaneously reports the refresh rate of the source.
|
|
|
|
|
Typical Applications
|
|
Colorimetry of automotive / aerospace displays
|
|
Colorimetry of paper, textile and printed samples
|
|
Source color temperature
|
|
Spectral reflectance and transmittance
|
|
Human factors / vision research
|
|
Incoming inspection
|
|
Production (on line) testing
|
|
LED color measurement
|
|
Automated testing
|
|
Medical / dental color measurements
|
|
Source refresh rate
|
|
|
|
All specifications are subject to change without notice
|
Specifications
|
|
Spectral Range
|
380 - 780 nm
|
|
Spectral Bandwidth
|
8 nm
|
|
Spectral Accuracy
|
± 2 nm
|
|
Wavelength Resolution
|
< 3.5 nm / pixel
|
|
Luminance Accuracy
|
± 2% of calculated luminance at 2856K @ 23° C
|
|
Color Accuracy when Measuring Illuminant A
|
±.0015 CIE 1931 x, ± .001 CIE 1931 y (.006 CIE 1931 x, y for CRT's typical)
|
|
Digital Resolution
|
14 bit (1 part in 16,000)
|
|
AutoSync Range
|
40 - 250 Hz
|
|
Measuring and Viewing Field
|
1° (measuring) and 7° (viewing) with MS- 75 lens at infinity focus
|
|
Battery
|
Rechargeable NiCad. Recharge rate - 1.5 hrs. from full discharge with CD-650
|
|
Interfaces
|
RS-232, IEEE-488 (optional)
|
|
Operating Temperature
|
34° to 95° F (1° to 35° C)
|
|
Operating Humidity
|
≤90% non-condensing
|
|
Size (approx. including MS-75 lens)
|
12" (305 mm)L x 7"(178 mm)W x 3" (76 mm) H
|
|
Weight (approx.)
|
4 lbs. 12 oz. (2.15 kg.) with MS-75 lens and battery
|
|
|
|
Field Coverage/Sensitivity
|
|
|
Accessory
|
Focus Distance
|
Spot Size
|
Sensitivity
|
|
MS-75 (14" to ∞)
|
14 " (355 mm)
1000 ft (305 m)
|
.208" (5.25 mm)
209" (5.32 m)
|
≥1.0 - ≤5,000 fl
≥3.4 - <17,000 cd/m²
|
|
SL-0.5X
|
3.6" (91.4 mm) to
5.4" (137 mm)
|
0.059" (1.5 mm) to
0.10" (2.54 mm)
|
≥1.0 - ≤5,000 fl
≥3.4 - ≤17,000 cd/m²
|
|
SL-1X
|
1.8" (46 mm) to
2.6" (66 mm)
|
0.035" (0.89 mm) to
0.052" (1.32 mm)
|
≥1.0 - ≤5,000 fl
≥3.4 - ≤17,000 cd/m²
|
|
MS-2.5X
|
1.81" (46 mm)
|
0.020" (0.51 mm)
|
≥3.0 - ≤10,000 fl
≥10.3 - ≤51,400 cd/m²
|
|
MS-5X
|
1.11 in. (28 mm)
|
0.011 in. (0.289 mm)
|
≥4 - ≤ 15,000 fl
≥13.7 - ≤ 51,400 cd/m²
|
|
CR-600 Cosine Receptor
|
N/A
|
N/A
|
≥2.0 - ≤12,000 fc
≥21.5 - ≤107,700 lux
|
|
LA-600 Luminance Adapter
|
Contact
|
0.52" (13.2 mm)
|
≥1.0 - ≤5,000 fl
≥3.4 - <17,000 cd/m²
|
|
FP-600 Fiber Probe
|
Contact
|
0.125" (3.17 mm)
|
≥2.5 - ≤12,000 fl
≥8.6 - ≤43,000 cd/m²
|
|
|
|
NOTES:
- For the ND-650-2 (Used only with the MS-75 or SL-1X or SL-0.5X), multiply the Sensitivity
by 100.
- All values calculated measuring Illuminant A at @ ³ 100:1 signal to noise (1% precision).
|
Software Options
|
|
|
|
6650-0002-00
|
SW-600 - SpectraWin™ Lite Operating Software
|
|
|
|
|
Full featured, menu driven, Windows software. Calculates luminance, CIE chromaticity,
correlated color temperature, dominant wavelength and excitation purity from measured
spectral data. Provides features such as graphically represented spectral distribution
and CIE color space (1931 and 1976), data manipulation (math functions) save/recall
binary or ASCII files, print graphics screens or tabular data, reflectance/ transmittance
L*a*b*u*v* measurements, ΔE Color Difference and Color Rendering Indices (CRI)
of lamp sources. Operates under Windows '98, 2000 or XP. All software is serialized
to an instrument. One licensed copy needs to be purchase per instrument.
|
|
|
|
6650-0002-09
|
SW-600-P - SpectraWin™ Pro Operating Software
|
|
|
|
|
Includes all of the capabilities of SpectraWin™ Lite and also features a Macro
Option allowing the end user to create macros that can generate automated test sequences.
One licensed copy per instrument must be purchased.
|
|
|
|
6650-0002-07
|
SpectraWin™ RGB DisplayCal Module
|
|
|
|
|
Optional module in SpectraWin™ Lite or Pro with all the capabilities of the
stand-alone RGB DisplayCal Software, details below. Must be purchase with SpectraWin.
One licensed copy per instrument must be purchased.
|
|
|
|
6650-0002-08
|
RGB DisplayCal Software
|
|
|
|
|
Stand-alone Windows based software designed for spectrally based white point calibrations
of CRT's, LCD's, PDP's and digital projectors. Calibration is based on "learned"
RGB values or user entered Y, xy, CCT values. Calibration is facilitated by on-screen
graphical feedback of an RGB bar graph or a moving color point within a CIE diagram.
One licensed copy per instrument must be purchased.
|
|
|
|
6650-0002-01
|
USC-600 - User Self-Calibration Software
|
|
|
|
|
Provides complete recalibration capabilities for the PR-650 including wavelength
accuracy, spectral intensity, linearity and accessory calibration. Requires a helium
wavelength calibration source (WC-600 or equivalent) and variable spectral radiance/
luminance standard (LRS-455 or equivalent). Supplied on 3 1/2" disks. Refer to the
PROML Price List for further information on the WC-600 and LRS-455. One licensed
copy per instrument must be purchased.
|
|
|
|
6650-0002-02
|
LabView Software Drivers for the PR-650
|
|
|
|
|
The LabView driver for the PR-650 is a virtual instrument (VI) and provides an interface
to the National Instruments LabView ™ environment. Using this driver capabilities
are provided for instrument setup, measurement control and data reporting. The package
includes documentation and software example. One licensed copy per instrument must
be purchased.
|
|
|
|
6650-0002-03
|
ICM-600-256 - Memory Card - 256K Byte
|
|
|
|
|
Includes system software and capability for up to 150 stored measurements (one standard
with PR-650).
|
|
|
|
6650-0002-04
|
ICM-600-512 - Memory Card - 512K Byte
|
|
|
|
|
Includes system software and capability for up to 600 stored measurements.
|
|
*Requires Calibration with Instrument
System Options
|
|
|
|
6650-0001-00
|
PR 650 - SpectraColorimeter (117 VAC - North American Plug)
|
|
|
|
|
|
Portable, battery powered, spectrally-based spot photometer/colorimeter for measurements
in the lab, on the production floor or in the field. A built LCD touch screen display
shows results based on radiance (or irradiance) measurements from 380-780 nm at
4 nm increments over an 8 nm bandwidth (5 nm BW optional) including a spectral power
distribution (SPD) of the measure data. Highly precise measurements can be made
at levels as low as 1 fL (3.4 cd/m²) using AutoSync™ and Adaptive Sensitivity®
(patented).
|
|
The Standard PR-650 System includes:
|
|
PR-650 SpectraColorimeter
|
|
MS-75 Lens
|
|
256K Integrated Circuit Memory Card
|
|
RS-232 Interface Cable
|
|
NiCad Rapid Charge Battery Pack
|
|
CD-600 Charger/Discharger
|
|
Save/Restore Software
|
|
Soft sided carrying case
|
|
NIST Traceable calibration (certified for six months)
|
|
Instruction Manual
|
|
|
|
|
|
6650-1001-00
|
PR-650 - SpectraColorimeter (240V AC Continental Europe Plug)
|
|
|
|
|
|
|
|
|
6650-2001-00
|
PR-650 - SpectraColorimeter (240V AC U.K./Ireland Plug)
|
|
|
|
|
|
|
|
|
6650-3001-00
|
PR-650 - SpectraColorimeter (100V AC Japan Plug)
|
|
|
|
|
|
|
|
|
6650-0003-00*
|
5 nm Bandwidth Option
|
|
|
|
|
|
Parameter
|
Standard PR-650
|
5 nm Bandwidth Option
|
|
System Bandwidth @ 588 nm (± 1 nm)
|
8 nm
|
5 nm
|
|
Threshold Luminance for Illuminant A @ 1% Precision *
|
1.0 fl (3.43 cd/m²)
|
2.0 fl (6.86 cd/m²)
|
|
Color Accuracy for Illuminant A
|
0.0015 CIE 1931 x, 0.0010 CIE 1931 y
|
0.0015 CIE 1931 x, 0.0010 CIE 1931 y
|
|
|
|
|
6650-0003-02*
|
RGB Option
|
|
|
|
|
Additional RAM card that adds interactive, non-contact display calibration, designed
to perform white point calibration of CRT's, LCD's, PDP's and digital projectors.
Calibrations are based on measured spectral radiance values from 380 to 780 nm at
4 nm increments. During calibration, the PR- 650 displays an RGB bar graph that
facilitates interactive calibration. The white point target is established by either
"learning" (measuring) a "golden" display, or by user entered target values such
as Luminance (Y), CIE 1931 xy and correlated color temperature (CCT). Standard measurement
capabilities such as radiance, luminance and chromaticity are included.
|
|
|
|
6650-0003-01*
|
Industrial Shutter Upgrade
|
|
|
|
|
The PR-650 Industrial Shutter Upgrade is ideal in environments where the PR-650
must perform continuous measurements 24 hours a day, seven days a week. This upgrade
consists of heavy-duty shutter assembly and special firmware.
Note: Complete calibration of the PR-650 is required following the shutter upgrade
and is not included with the upgrade. Consult factory.
|
|
|
|
6650-0003-03*
|
Aperture Option - ½°
|
|
|
|
|
This option provides a measuring aperture that is one-half the diameter of the standard
PR-650 1° aperture. Ideal for measuring areas that may be too small for the standard
PR-650.
|
|
*Requires Calibration with Instrument
Optical Accessories
|
|
|
|
6650-0008-00*
|
CR-600 - Cosine Receptor
|
|
|
|
For cosine corrected illuminance/irradiance measurements. Replaces the MS-75 lens
during use.
|
|
|
|
6650-0008-01
|
FH-600 - Filter Holder
|
|
|
|
|
Designed to hold two 2" x 2" (51 mm x 51 mm) filters. Ideal for filter transmission
measurements. Threads into the MS-75 or SL-1X lenses.
|
|
|
|
6650-0008-02*
|
FP-600 - Flexible Probe
|
|
|
|
2 foot (60.9 cm) long probe designed for contact measurements of luminance and radiance.
Probe tip is 0.125" (3.18 mm) diameter. Replaces the MS-75 during use.
|
|
|
|
6650-0008-03*
|
IS-600 - Integrating Sphere
|
|
|
|
This 3" (76.2 mm) integrating sphere is designed to measure small point sources
(e.g. miniature lamps, LED's, etc.) over 4p steradians. Calibrated for Radiant Flux(watts)
and Luminous Flux(lumens), color temperature, xy coordinated and spectral data.
Accepts 0.125" (3.18mm) and 0.250" (6.36mm) sources and replaces the MS-75 during
use. Consult factory for other special sizes.
|
|
|
|
6650-0008-04*
|
ICC-600 - Integrating Cosine Corrector
|
|
|
|
This 3" (76.2 mm) integrating sphere features a 1 inch (25.4 mm) entrance port and
is designed for applications where the integrated measurements of point sources
is required. The sphere is fully baffled to insure complete integration of the incoming
radiant energy. Calibrated for Irradiance (watts /meter2) and Illuminance (footcandles
and lux).
|
|
|
|
6650-0008-05*
|
LA-600 - Luminance Adapter
|
|
|
|
Contact measurements for luminance and radiance are performed with this adapter
which covers 0.52" (13.2 mm). Replaces the MS-75 during use.
|
|
|
|
6650-0008-17
|
LR-55 - LED Receptor
|
|
|
|
|
Designed to measure discrete LED's, the accessory accepts 0.125" (3.18 mm) diameter
and 0.25" (6.36 mm) diameter LED's. Calibrated for radiant intensity (uw * sr-1)
and luminous intensity (millicandela) with an 8° acceptance angle. Replaces the
MS-55 during use. Consult factory for alternate LED diameters.
|
|
|
|
6650-0008-18
|
LR-127 - CIE 127 - LED Analyzer
|
|
|
|
This patented optical accessory is designed to test discrete LED's for compliance
to CIE 127. Tests both conditions A (far) and B (near) of the CIE recommendation.
Calibrated for luminous intensity (millicandelas). Both conditions can be tested
with the flip of a lever from 'A' to 'B'. No need to change tubes or even remove
the LED between tests. Accepts T1 (3 mm) and T1.75 (5 mm) packages. Replaces the
MS-55 during use. Consult factory for alternate LED packages.
|
|
|
|
6650-0008-08*
|
MS-2.5X - MicroSpectar™ Lens
|
|
|
|
|
2.5X magnification, fixed focus lens for luminance/radiance measurements. Replaces
the MS-75 lens during use. Provides 0.020" (0.51 mm) field coverage at a 1.81" (46
mm) working distance. Replaces the MS-75 during use.
|
|
|
|
6650-0008-15*
|
MS-5X - MicroSpectar™ Lens
|
|
|
|
|
5X magnification, fixed focus lens for luminance/radiance measurements. Replaces
the MS-75 lens during use. Provides 0.011" (0.289 mm) field coverage at a 1.11"
(28 mm) working distance. Replaces the MS-75 during use.
|
|
|
|
6650-0008-09*
|
MS-75 - MacroSpectar® Lens
|
|
|
|
|
C mount lens focusable from 14" (0.25X magnification) to infinity. Field coverage
at 14" is 0.208" (5.25 mm). This is the Standard Objective Lens for the PR-650.
|
|
|
|
6650-0008-07*
|
ND-600-1 - Neutral Density Filter - ND1
|
|
|
|
|
This 10X attenuator is used for measuring samples exceeding approximately 5,000
fL. It can be mounted on either the MS-75 or SL-1X lenses. Attenuates the signal
by approximately 10X.
|
|
|
|
6650-0008-06*
|
ND-600-2 - Neutral Density Filter - ND2
|
|
|
|
|
This 100X attenuator is used for measuring samples exceeding approximately 50,000
fL. It can be mounted on either the MS-75 or SL-1X lenses. Attenuates the signal
by approximately 100X.
|
|
|
|
6650-0008-16*
|
ND-600-3 - Neutral Density Filter - ND3
|
|
|
|
|
This 1000X attenuator is used for measuring samples exceeding approximately 500,000
fL. It can be mounted on either the MS-75 or SL-1X lenses. Attenuates the signal
by approximately 1000X.
|
|
|
|
6650-0008-10*
|
SL-0.5X - Supplementary Lens
|
|
|
|
|
0.5X magnification lens that provides a field coverage halfway between the MS-75
and SL-1X lenses. The working distance is 3.6" (91.4 mm) - 5.4" (137 mm) for a field
coverage range from 0.059" (1.5mm) - 0.10" (2.54 mm). Threads into the MS-75 during
use.
|
|
|
|
6650-0008-11*
|
SL-1X - Supplementary Lens
|
|
|
|
|
1X magnification, fixed focus lens for luminance/radiance measurements. Threads
into the MS-75 lens during use. Provides a working distance range from 1.8" (46
mm) - 2.6" (66 mm) for a field coverage range of 0.035" (0.89 mm) - 0.052" (1.32
mm)
|
|
|
|
6650-0008-12*
|
MS-7.5 mm - MacroSpectar® Wide-Field Lens
|
|
|
|
|
C mount lens with a 3.94" minimum working distance (0.025X magnification) to infinity.
Field coverage at 3.94" is 0.69" (17.5mm). This lens is suitable for large area
coverage at short distance for non-contact color quality control (L*a*b*) measurements.
|
|
|
|
6650-0008-13
|
RS-3 - Reflectance Standard
|
|
|
|
|
2" diameter (51 mm diameter) PTFE reflectance standard used for making ambient light
measurements, measurements of point sources (e.g. lamps) or measurements of the
illuminating source for reflectance or L*a*b* calculations. The RS-3 is uncalibrated,
meaning that all spectral reflectance correction factors are set to 1.00. SAE ¼
- 20 thread, black anodized, aluminum case.
|
|
|
|
6650-0008-14
|
SRS-3 - Spectrally Calibrated Reflectance Standard
|
|
|
|
|
All the capabilities of the RS-3 and calibrated for absolute spectral reflectance.
Includes reflectance factors and certificate of calibration.
|
|
*Requires Calibration with Instrument
Miscellaneous Accessories
|
|
|
|
6650-0009-00
|
AC-600 - AC Adapter and Rapid Charger (with 117 VAC North American Power Cord)
|
|
|
|
|
AC Adapter (battery eliminator) and intelligent rapid battery charger (2 batteries
in one hour or less depending on existing charge). Contains circuitry that prevents
overcharging battery. Universal AC input.
|
|
|
|
6650-1009-00
|
AC-600 - AC Adapter and Rapid Charger (with 240 VAC Continental Europe Power Cord)
|
|
|
|
|
|
|
|
|
6650-0009-01
|
AA-600 - DC to AC Adapter
|
|
|
|
|
Allows the PR-650 to be powered from a 12 Volt car battery via a plug-in converter.
Converts 12 Volts DC to 117 Volts AC (140 watts continuous)
|
|
|
|
6650-0009-02
|
CD-600 - Charger/Discharger (Universal AC input)
|
|
|
|
|
Rapid charger that can charge the NiCad battery in approx. 2 hours. Also, Allows
the user to discharge the battery fully before charging. (117 VAC - North American
Plug
|
|
|
|
6650-1009-02
|
CD-600 - Charger/Discharger (Universal AC input)
|
|
|
|
|
(240 VAC Continental Europe Plug)
|
|
|
|
6650-2009-02
|
CD-600 - Charger/Discharger (Universal AC input)
|
|
|
|
|
(240 VAC Continental U.K./Ireland Plug)
|
|
|
|
6650-3009-02
|
CD-600 - Charger/Discharger (Universal AC input)
|
|
|
|
|
(100 VAC - Japan)
|
|
|
|
6650-0009-03
|
BE-600 - AC Adapter (with 117 VAC North American Power Cord)
|
|
|
|
|
10 ft. AC Adapter (battery eliminator) with universal AC input.
|
|
|
|
6650-0009-16
|
BE-600-25 - AC Adapter (with 117 VAC North American Power Cord)
|
|
|
|
|
25 ft. AC Adapter (battery eliminator) with universal AC input.
|
|
|
|
6650-1009-03
|
BE-600 - AC Adapter (10 ft. with 240 VAC Continental Europe Power Cord)
|
|
|
|
|
|
|
|
|
6650-0009-04
|
BP-600 - Battery Pack
|
|
|
|
Spare battery for PR-650. Up to 2 hours continuous operation. Standard equipment
with the PR-650.
|
|
|
|
6650-0009-05
|
BPX-600 - Battery Pack Extended-Use
|
|
|
|
|
The battery pack is a lead-acid battery that provides the proper current required
to operate the PR-650. The battery pack renders more than 20 hours of operation
in remote locations where an AC power source is not available or inconvenient. The
dimensions are 7.87" X 4.72" X 2.95" (19.9 cm X 11.8 cm X 7.8 cm) and 5 lbs 13 oz.
|
|
|
|
6650-0009-06
|
CC-600 - Molded Carrying Case
|
|
|
|
|
Fiberglass carrying case with molded foam inserts offering maximum protection for
the PR-650 and accessories.
|
|
|
|
6650-0009-07
|
SS-CC-600 - Soft Sided Carrying Case
|
|
|
|
|
Camera bag type with shoulder strap. Standard equipment with the PR-650.
|
|
|
|
6650-0009-08
|
DC-600 - Power Supply Adapter
|
|
|
|
|
This battery eliminator is designed for use with a linear power supply. It consists
of a pseudo battery and three leads (pos., neg., and tracking) for use with most
DC supplies. Requires a 13 VDC @ 800 mA linear supply tracking or non-tracking type.
|
|
|
|
6650-0009-09
|
GPIB-232 - Interface IEEE-488 to RS-232 (100 - 117 VAC, with North American Power
Cord)
|
|
|
|
|
Use this accessory to control the PR-650 from an IEEE-488 interface bus using Remote
Mode software ASCII commands. RS-232 (e.g. parity, baud rate, stop bits) and IEEE-488
(e.g. IEEE-488 address, talk/talk listen) configuration parameters can be manually
set. Includes:
- Interface with IEEE-488 connector and 9 pin sub D RS-232 connector, on/off switch
and configuration dip switches.
- Instruction Manual
|
|
|
|
6650-1009-09
|
GPIB-232 - Interface IEEE-488 to RS-232
|
|
|
|
|
(220 - 240 VAC, with Continental Europe Power Cord)
|
|
|
|
6650-0009-10
|
IFC-600 - RS-232 Interface Cable
|
|
|
|
|
Used for SpectraWin, Remote Mode software and SAVE/RESTORE functions. 25 pin sub-D
female connector on Host (PC) side. Standard equipment with the PR-650.
|
|
|
|
6650-0009-11
|
PC-600 - RS-232 Printer Cable
|
|
|
|
|
Designed to connect an RS-232 printer to the PR-650 for tabular printouts when using
the PR-650 in a stand alone configuration (not attached to a Host computer). Provided
with a 25-pin sub D female connector.
|
|
|
|
6650-0009-12
|
Integrated Camera Adapter Kit - 600 (Black & White Camera and Black & White
Monitor)
|
|
|
|
|
This kit is ideal for remote viewing of the area being measured. The kit consists
of a camera, mounting hardware, power supply, cable harness and 12" monitor that
can be easily installed by the user. The CCD camera is integrated into the viewing
optics to provide a magnified view of the Pritchard mirror alignment against the
item being measured. This is ideal for automated test environments where the optical
head may not be easily accessed.
|
|
|
|
6650-0009-13
|
Integrated Camera Adapter Kit - 600 (Color Camera and Color Monitor)
|
|
|
|
|
|
|
|
|
6650-0009-14
|
USB Adapter - USB to Serial Port Connector for the PR-650.
|
|
|
|
|
|
|
|
|
6650-0009-15
|
TR-15 - Tripod
|
|
|
|
|
Fully adjustable tripod with SAE 1/4 - 20 screw mount for stable measurements with
the SpectraScan when an optical table or bench is not available.
|
|
*Requires Calibration with Instrument
|