Unique Design
|
|
For nearly 15 years, the PR-650 SpectraScan has been the
most widely used spectroradiometer in the world - the workhorse of the industry.
The new PR-655 replaces the world renowned PR-650 with a
plethora of enhancements. This unique, portable battery powered instrument utilizes
a fast-scanning 128 detector element spectrometer with a spectral resolution of
3.12 nm per pixel and is supplied with an automated measure shutter. A 1° aperture
is standard equipment with the PR-655 - an optional ½° aperture can be ordered.
Other hardware features include AutoSync® for automatically
synchronizing to the source refresh rate insuring the utmost accuracy, an optional
External Trigger port allowing remote measurement activation from
either a push button or peripheral device, a Secure Digital (SD)
port for measurement storage, and a long lasting rechargeable Lithium-Ion (Li-Ion)
battery.
|
|
Easy to Use
|
|
The PR-655 menus are accessed via the on-board, 2.25" x 3" high resolution, full
color touch screen LCD display and 5-way navigation keypad. Following a measurement,
the PR-655 displays data and color spectral graphs on the system display. The PR-655
design provides stand alone operation - no PC required. The PR-655 can be also be
controlled via the world famous SpectraWin™ 2
software or by using text based commands (Remote Mode). All communications are via
the standard USB interface or the optional Bluetooth or RS-232 interface.
|
|
Flexibility
|
The unique design of the PR-655 makes tasks such as spectrally based photometric
and colorimetric measurements, source spectral power distribution, dominant wavelength
and correlated color temperature quick and simple.
For applications other than radiance or luminance the PR-655 can be supplied with
optical accessories such as a cosine receptor for irradiance / illuminance,
LR-127 LED Analyzer for testing LED's to CIE 127, fiber probe for remote
non-line-of-sight luminance testing, and a series of magnification lenses for small
spot size analysis. In fact, all of the accessories available for the
PR-650 SpectraScan can be used on the PR-655. An RGB option is available
that provides an interactive method for display white point calibration based on
spectral measurements.
|
|
Wide Dynamic Range
|
|
The PR-655 provides a dynamic range of 0.2 fL to 30,000 fL, without the need
for any external neutral density filters. Ideal for contrast and brightness measurements
of display panels and a wide spectrum of other target devices.
|
|
Connectivity
|
|
It's easy for the PR-655 to talk to the outside world - it comes equipped with USB
and Bluetooth® (optional) wireless
interfaces. It is supplied with text based, Remote Mode syntax and a driver that
emulates an RS-232 interface (COM: port) making it a simple task to generate custom
programming to perform specific tasks or for inclusion in an ATE environment. If
required, an optional traditional RS-232 Interface can be added.
|
|
|
|
Typical Applications, Features & Benefits
|
|
Applications
|
|
Display luminance and color
|
|
Contrast
|
|
Projector Calibration
|
|
LED testing
|
|
Paper, ink and textile testing
|
|
Film and Video Post-Production
|
|
Medical / dental color testing
|
|
Reflectance / transmittance
|
|
Digital Cinema
|
|
Human factors
|
|
Dominant wavelength
|
|
Automotive and Aerospace Display Testing
|
|
|
Features
|
|
Full Color Touch Screen Display
|
|
Wide Dynamic Range
|
|
USB Interface
|
|
Bluetooth ready (optional)
|
|
Long lasting rechargeable Li-Ion battery
|
|
SD Memory
|
|
|
Benefits
|
|
Easy-to-use menu based software
|
|
Address almost any display measurement requirement
|
|
Connects to virtually any PC
|
|
Wireless, remote data transfer
|
|
Excellent for field use.
|
|
Save thousands of measurements
|
|
|
Specifications
|
|
Detector
|
128 detector array
|
|
Spectroradiometer Wavelength Range
|
380 to 780 nm
|
|
Optics
|
Pritchard optical system.
|
|
Digital Resolution
|
16 bits
|
|
Spectral Resolution
|
3.12 nm / pixel
|
|
Spectral bandwidth
|
8 nm (5 nm optional)
|
|
Spectral Accuracy
|
± 1 nm
|
|
Luminance Range
|
0.2 - 30,000 fL
|
|
Luminance accuracy (Against NIST luminance standard)
|
± 2%
|
|
Luminance repeatability
|
≤ 1%
|
|
Color Accuracy (for Illuminant A)
|
±0.0015 in CIE 1931 x,y
|
|
Measurement Capabilities
|
Luminance, Illuminance, luminous intensity, chromaticity, correlated color temperature,
dominant wavelength.
|
|
Measurement Time
|
3 ms to 6000ms (6 secs)
|
|
AutoSync Range
|
20 to 400 Hz.
|
|
Battery
|
Rechargeable Lithium-Ion. (≥ 12 hours continuous operation)
|
|
Weight
|
3.75 lbs (1.7 kg)
|
|
Operating Temperature
|
34° to 95° F (1° to 35° C)
|
|
|
|
Measurement Spot Size
|
|
|
|
Aperture
|
|
Accessory
|
Working Distance
|
1°
|
0.5°
|
MS-75
(355 mm to infinity)
|
355 mm
305 m
|
5.25 mm
5.32 m
|
2.63 mm
2.66 m
|
|
SL-0.5x
|
94.1 mm
to
137 mm
|
1.5 mm
to
2.54 mm
|
0.75 mm
to
1.27 mm
|
|
SL-1x
|
46 mm
to
66 mm
|
0.890 mm
to
1.32 mm
|
0.445 mm
to
0.660 mm
|
|
MS-2.5x
|
46 mm
|
0.51 mm
|
0.225 mm
|
|
MS-5x
|
28 mm
|
0.289 mm
|
0.145 mm
|
MS-7.5
(100 mm to infinity)
|
100 mm
30.5 m
|
17.5 mm
53 cm
|
8.75 mm
26.6 cm
|
|
LA-655
|
Contact
|
13.2 mm
|
13.2 mm
|
|
FP-655
|
Contact
|
3.17 mm
|
3.17 mm
|
|
|
|
Luminance Range (fL)
|
|
|
Aperture
|
|
Accessory
|
1°
|
0.5°
|
|
MS-75
|
0.2 to 30,000
|
0.8 to 120,000
|
|
SL-0.5x
|
0.2 to 30,000
|
0.8 to 120,000
|
|
SL-1x
|
0.2 to 30,000
|
0.8 to 120,000
|
|
MS-2.5x
|
0.5 to 72,000
|
2.0 to 288,000
|
|
MS-5x
|
0.8 to 120,000
|
3.2 to 480,000
|
|
MS-7.5
|
0.2 to 30,000
|
0.8 to 120,000
|
|
LA-655
|
0.2 to 30,000
|
0.8 to 120,000
|
|
FP-655
|
0.5 to 75,000
|
1.6 to 300,000
|
|
CR-655
|
0.4 to 60,000 fc
|
1.6 to 240,000 fc
|
|
|
|
Software Options
|
|
|
|
6655-0002-00
|
SW-655 - SpectraWin™ 2 Lite Operating Software
|
|
|
|
|
Full featured, menu driven, Windows software. Calculates luminance, CIE chromaticity,
correlated color temperature, dominant wavelength and excitation purity from measured
spectral data. Provides features such as graphically represented spectral distribution
and CIE color space (1931 and 1976), data manipulation (math functions) save/recall
binary or ASCII files, print graphics screens or tabular data, reflectance/ transmittance
L*a*b, L*u*v* measurements, ΔE Color Difference and Color Rendering Indices
(CRI) of lamp sources. Operates under Windows XP (Windows XP Professional recommended).
All software is serialized to an instrument. One licensed copy needs to be purchase
per instrument.
|
|
|
|
6655-0002-01
|
SW-655-P - SpectraWin™ 2 Pro Operating Software
|
|
|
|
|
Includes all of the capabilities of SpectraWin™ 2 Lite and also features a
Macro Option allowing the user to create macros that can generate automated test
sequences
One licensed copy per instrument must be purchased.
|
|
|
|
6655-0002-02
|
SpectraWin™ 2 RGB DisplayCal Module
|
|
|
|
|
Optional module in SpectraWin™ 2 Lite or Pro designed for spectrally based
white point calibrations of CRT's, LCD's, PDP's and digital projectors. Calibration
is based on "learned" RGB values or user entered Y, xy, CCT values. Calibration
is facilitated by on-screen graphical feedback of an RGB bar graph or a moving color
point within a CIE diagram. Must be purchase with SpectraWin™ 2.
One licensed copy per instrument must be purchased.
|
|
|
|
6655-0002-08
|
SpectraWin 2 Lite to Pro Upgrade
|
|
|
|
|
|
|
|
|
6655-0002-03
|
PR-655 Dynamic Link Library (.DLL)
|
|
|
|
|
Fully documented library that can be used in C++, Visual Basic, and LabView applications
for measurement control and data transfer from the PR-655.
Includes SpectraWin™ 2 Lite software. One licensed copy per instrument must
be purchased.
|
|
|
|
6655-0002-04
|
USC-655 - User Self-Calibration Software
|
|
|
|
|
Provides complete recalibration capabilities for the PR-655 including wavelength
accuracy, spectral intensity, linearity and accessory calibration. Requires a helium
wavelength calibration source (WC-600 or equivalent) and variable spectral radiance/
luminance standard (LRS-455 or equivalent). Supplied on
a CD.
Refer to the PROML Price List for further information on
the WC-655 and LRS-455.
One licensed copy per instrument must be purchased.
|
|
|
|
6655-0002-05
|
USC-655-5
|
|
|
|
|
5 licenses for the USC-655 calibration software.
For existing units, serial numbers must be provided at time of purchase.
|
|
|
|
6655-0002-06
|
USC-655-10
|
|
|
|
|
10 licenses for the USC-655 calibration software.
For existing units, serial numbers must be provided at time of purchase.
|
|
|
System Options
|
|
|
|
6655-0001-00
|
PR-655 - SpectraScan (117 VAC - North American Plug)
|
|
|
|
|
|
Portable, battery powered, spectrally-based spot photometer/spectroradiometer for
measurements in the lab, on the production floor or in the field. A built LCD touch
screen display shows results based on radiance (or irradiance) measurements from
380-780 nm at 4 nm increments over an 8 nm bandwidth (5 nm BW optional) including
a spectral power distribution (SPD) of the measure data. Highly precise measurements
can be made at levels as low as 0.2 fL (0.7 cd/m²) using AutoSync™ and
Adaptive Sensitivity® (patented).
|
|
The Standard PR-655 System includes:
|
|
PR-655 SpectraScan
|
|
MS-75 Lens
|
|
1° Aperture
|
|
AutoSync®
|
|
Secure Digital (SD) Card
|
|
BP-655, Li-Ion Rechargeable Battery
|
|
AC-655-6, A/C Adapter (6 ft.) with North American/Japanese cord.
90 - 240 VAC, 50 / 60 Hz input
|
|
CD with drivers and Instruction Manual
|
|
Soft sided carrying case
|
|
NIST Traceable calibration
|
|
|
|
|
|
6655-1001-00
|
PR-655 - SpectraScan (Continental Europe Plug)
|
|
|
|
|
|
|
|
|
6655-2001-00
|
PR-655 - SpectraScan (U.K./Ireland/Hong Kong/Singapore Plug)
|
|
|
|
|
|
|
|
|
6655-3001-00
|
PR-655 - SpectraScan (Australia / New Zealand Plug)
|
|
|
|
|
|
|
|
|
6655-0003-00*
|
5 nm Bandwidth Option
|
|
|
|
|
|
6655-0003-01
|
BT-655 Bluetooth
|
|
|
|
|
Class 1 extended range (up to 100 meters) USB BlueTooth adapter for the host computer
and Photo Research device driver. Works well with SpectraWin™ 2 and remote
mode.
|
|
|
|
6655-0003-02*
|
Aperture Option - 0.5°
|
|
|
|
|
This option provides a measuring aperture that is one-half the diameter of the standard
PR-655 1° aperture. Ideal for measuring areas that may be too small for the
standard PR-655.
|
|
|
|
6655-0003-03
|
RS-232 Port
|
|
|
|
|
Adds a port to connect to RS-232 devices. Includes a 3 meter cable terminated on
one end with a 9 pin sub-D female connector.
|
|
|
|
6655-0003-04
|
RGB Option
|
|
|
|
Adds the ability to perform interactive white point calibration of CRT's, LCD's,
PDP's and digital projectors. Calibrations are based on measured spectral radiance
values from 380 to 780 nm at 4 nm increments. During calibration, the PR-655 displays
an RGB bar graph that facilitates interactive calibration. The white point target
is established by either "learning" (measuring) a "golden" display or by user entered
target values such as Luminance (Y), CIE 1931 x, y and correlated color temperature
(CCT). Standard measurement capabilities such as radiance, luminance and chromaticity
are included.
|
|
|
|
6655-0003-05
|
TG-OPT - External Trigger Option
|
|
|
|
|
Used to externally trigger a PR-655 measurement and to simultaneously send a pulse
to a remote device such as a strobe light. Trigger cable not included. See
Connectivity Accessories.
|
|
|
|
6655-0003-06
|
UV-655
|
|
|
|
|
Changes the measured spectral range from 380 - 780 nm to 360 - 760 nm thereby enhancing
the near UV response of the instrument.
|
|
|
|
6655-0003-12
|
CIE Color Chart
|
|
|
|
Displays full color CIE 1931 Chromaticity Diagram with measured point following
a measurement on the instrument.
|
|
|
|
6655-0003-09
|
CIE Pass / Fail
|
|
|
|
Create regions in the CIE 1931 chromaticity diagram that act as Pass / Fail criteria.
If the measured color falls in the specified region, Pass is reported on the instrument
display or Fail if the measured point falls outside the region. The measured point
and region are also displayed on a color 1931 CIE diagram. Regions can be defined
as squares, rectangles, polygons (3 - 10 sides), circles or ellipses. When not enabled,
a full color CIE 1931 Chromaticity Diagram with measured point is displayed.
|
|
|
|
6655-0003-10
|
Color Rendering Index (CRI)
|
|
|
|
Calculate all 14 CRI indices and the average CRI (using indices 1 - 8). User selectable
or automatically generated reference. CCT and chromaticity tolerances are also set
by the operator. Results are reported on the instrument display.
|
|
|
*Requires Calibration with Instrument
|
|
Luminance Accessories - Lenses
|
|
|
|
6655-0008-15*
|
MS-75 - MacroSpectar® Lens
|
|
|
|
C mount lens focusable from 14" (0.25X magnification) to infinity. Field coverage
at 14" is 0.208" (5.25 mm). This is the Standard Objective Lens for the PR-655.
|
|
|
|
6655-0008-16*
|
SL-0.5X - Supplementary Lens
|
|
|
|
|
0.5X magnification lens that provides a field coverage halfway between the MS-75
and SL-1X lenses. The working distance is 3.6" (91.4 mm) - 5.4" (137 mm) for a field
coverage range from 0.059" (1.5mm) - 0.10" (2.54 mm). Threads into the MS-75 during
use.
|
|
|
|
6655-0008-17*
|
SL-1X - Supplementary Lens
|
|
|
|
|
1X magnification, fixed focus lens for luminance/radiance measurements. Threads
into the MS-75 lens during use. Provides a working distance range from 1.8" (46
mm) - 2.6" (66 mm) for a field coverage range of 0.035" (0.89 mm) - 0.052" (1.32
mm)
|
|
|
|
6655-0008-18*
|
MS-2.5X - MicroSpectar™ Lens
|
|
|
|
|
2.5X magnification, fixed focus lens for luminance/radiance measurements. Replaces
the MS-75 lens during use. Provides 0.020" (0.51 mm) field coverage at a 1.81" (46
mm) working distance. Replaces the MS-75 during use.
|
|
|
|
6655-0008-19*
|
MS-5X - MicroSpectar™ Lens
|
|
|
|
|
5X magnification, fixed focus lens for luminance/radiance measurements. Replaces
the MS-75 lens during use. Provides 0.011" (0.289 mm) field coverage at a 1.11"
(28 mm) working distance. Replaces the MS-75 during use.
|
|
|
|
6655-0008-20*
|
MS-7.5 mm - MacroSpectar® Wide-Field Lens
|
|
|
|
|
C mount lens with a 3.94" minimum working distance (0.025X magnification) to infinity.
Field coverage at 3.94" is 0.69" (17.5mm). This lens is suitable for large area
coverage at short distance for non-contact color quality control (L*a*b*) measurements.
|
|
|
*Requires Calibration with Instrument
|
|
Luminous Flux Accessories
|
|
|
|
6655-0008-07*
|
IS-655 - 3" Integrating Sphere
|
|
|
|
This 3" (76.2 mm) integrating sphere is designed to measure small point sources
(e.g. miniature lamps, LED's, etc.) over 4π steradians. Calibrated for Radiant
Flux(watts) and Luminous Flux(lumens), color temperature, xy coordinated and spectral
data. Accepts 0.125" (3.18mm) and 0.250" (6.36mm) sources and replaces the MS-75
during use. Consult factory for other special sizes.
|
|
|
*Requires Calibration with Instrument
|
|
Luminous Intensity Accessories
|
|
|
|
6655-0008-13
|
LR-55 - LED Receptor
|
|
|
|
|
Designed to measure discrete LED's, the accessory accepts 0.125" (3.18 mm) diameter
and 0.25" (6.36 mm) diameter LED's. Calibrated for radiant intensity (µw *
sr-1) and luminous intensity (millicandela) with an 8° acceptance
angle. Replaces the MS-55 during use. Consult factory for alternate LED diameters.
|
|
|
|
6655-0008-14*
|
LR-127 - CIE 127 - LED Analyzer
|
|
|
|
This patented optical accessory is designed to test discrete LED's for compliance
to CIE 127. Tests both conditions A (far) and B (near) of the CIE recommendation.
Calibrated for luminous intensity (millicandelas). Both conditions can be tested
with the flip of a lever from 'A' to 'B'. No need to change tubes or even remove
the LED between tests. Accepts T1 (3 mm) and T1.75 (5 mm) packages. Replaces the
MS-75 during use. Consult factory for alternate LED packages.
|
|
|
*Requires Calibration with Instrument
|
|
Filters
|
|
|
|
6655-0008-00*
|
ND-655-0.3 - Neutral Density Filter - ND-0.3
|
|
|
|
|
This ND filter attenuates the signal by approximately 2 times (50% transmission).
The ND-655-0.3 can be mounted on either the MS-75 or SL-1X lenses.
|
|
|
|
6655-0008-01*
|
ND-655-0.7 - Neutral Density Filter - ND-0.7
|
|
|
|
|
This ND filter attenuates the signal by approximately 5 times (20% transmission).
The ND-655-0.7 can be mounted on either the MS-75 or SL-1X lenses.
|
|
|
|
6655-0008-02*
|
ND-655-1 - Neutral Density Filter - ND-1
|
|
|
|
|
This ND filter attenuates the signal by approximately 10 times (10% transmission).
The ND-655-1 can be mounted on either the MS-75 or SL-1X lenses.
|
|
|
|
6655-0008-03*
|
ND-655-2 - Neutral Density Filter - ND-2
|
|
|
|
|
This ND filter attenuates the signal by approximately 100 times (1% transmission).
The ND-655-2 can be mounted on either the MS-75 or SL-1X lenses.
|
|
|
|
6655-0008-04*
|
ND-655-3 - Neutral Density Filter - ND-3
|
|
|
|
|
This ND filter attenuates the signal by approximately 1000 times (0.1% transmission).
The ND-655-3 can be mounted on either the MS-75 or SL-1X lenses.
|
|
|
|
6655-0008-29*
|
ND-655-4 - Neutral Density Filter - ND-4
|
|
|
|
|
This ND filter attenuates the signal by approximately 10,000 times (0.01% transmission).
The ND-655-4 can be mounted on either the MS-75 or SL-1X lenses.
|
|
|
|
6655-0008-11
|
FH-655 - Filter Holder
|
|
|
|
|
Designed to hold two 2" x 2" (51 mm x 51 mm) filters. Ideal for filter transmission
measurements. Threads into the MS-75 or SL-1X lenses.
|
|
|
*Requires Calibration with Instrument
|
|
Reflectance Standards
|
|
|
|
6655-0008-05*
|
RS-3 - Reflectance Standard
|
|
|
|
|
2" diameter (51 mm diameter) PTFE reflectance standard used for making ambient light
measurements, measurements of point sources (e.g. lamps) or measurements of the
illuminating source for reflectance or L*a*b* calculations. The RS-3 is uncalibrated,
meaning that all spectral reflectance correction factors are set to 1.00. SAE ¼
- 20 thread, black anodized, aluminum case.
|
|
|
|
6655-0008-06*
|
SRS-3 - Spectrally Calibrated Reflectance Standard
|
|
|
|
|
All the capabilities of the RS-3 and calibrated for absolute spectral reflectance
@ 45. Includes reflectance factors and certificate of calibration.
|
|
|
*Requires Calibration with Instrument
|
|
Connectivity Accessories
|
|
|
|
6655-0009-08
|
TG-10 - 10 ft (3.05 m) Trigger Cable
|
|
|
|
|
Used for externally triggering a PR-655 measurement, and to simultaneously send
a pulse to a remote device such as a strobe lamp. 10 foot cable terminated with
a 6 pin mini-DIN connector.
|
|
|
|
6655-0009-09
|
USB-3 - 3 ft (0.91 m) USB Interconnecting Cable
|
|
|
|
|
|
|
|
|
6655-0009-10
|
USB-10 - 10 ft (3.05 m) USB Interconnecting Cable
|
|
|
|
|
|
|
|
|
6655-0009-11
|
GPIB-USB Interface
|
|
|
|
|
Converts USB to GPIB (IEEE-488) protocol. Interface cable not included
|
|
|
|
6655-0009-18
|
BTA-655 - Blue Tooth Adapter
|
|
|
|
|
Class 1 extended range (up to 100 meters) USB Blue Tooth adapter for the host computer.
Works well with SpectraWin™ 2 and Remote Mode.
|
|
|
|
6655-0009-21
|
RS232 (DB9F) to RJ-12 Connector
|
|
|
|
|
Interconnector for RS232 Cable from PR-655 to PC.
|
|
|
|
6655-0009-22
|
RS232 Cable - 6 Meter
|
|
|
|
|
6 meter RS232 cable terminated at both ends with RJ-12 connectors.
|
|
|
|
6655-0009-23
|
RS232 Cable - 10 Meter
|
|
|
|
|
10 meter RS232 cable terminated at both ends with RJ-12 connectors.
|
|
|
|
6655-0009-19
|
USB-15 - 15 ft. (4.57 m) USB Cable
|
|
|
|
|
|
|
|
|
6655-0009-20
|
USB-EXT - 16 ft. (4.88 m) USB Extension Cable
|
|
|
USB active extension cable. A maximum of 4 cables can be used. Requires 6655-0009-19
standard 15 ft. cable be purchased.
|
|
|
|
|
System Power Accessories
|
|
|
|
6655-0009-00
|
AC-655-6 AC Adapter with 6 foot Cord (Standard with the PR-655)
|
|
|
|
|
(with 117 VAC North American Power Cord). 90 - 240 VAC input.
|
|
|
|
6655-0009-01
|
AC-655-20 AC Adapter with 25 foot Cord
|
|
|
|
|
(with 117 VAC North American Power Cord). 90 - 240 VAC input.
|
|
|
|
6655-0009-02
|
BP-655 - Li-Ion Rechargeable Battery (Standard with the PR-655)
|
|
|
|
|
Lithium-Ion battery for the PR-655. 12 hours of continuous with a full charge.
|
|
|
|
6655-0009-03
|
CD-655 - Charger/Discharger (Universal AC input)
|
|
|
|
|
Rapid charger that can charge the Li-Ion battery in approx. 4 hours. Standard charge
time in the instrument is 8 - 12 hours from a total discharge.
|
|
|
Data Storage Accessories
|
|
|
|
6655-0009-04
|
SD - Secure Digital Card
|
|
|
|
|
|
|
|
|
6655-0009-05
|
SD-R - USB SD Card Reader
|
|
|
|
|
For use when transferring measurement data from the PR-655 to a PC. USB cable not
included.
|
|
|
Miscellaneous Accessories
|
|
|
|
6655-0009-12
|
CK-655 - Integrated Color Camera Kit (Color Camera, No Monitor)
|
|
|
|
|
This kit provides a means of remotely viewing the measurement scene through the
eyepiece of the PR-655. Includes an adapter for mounting the camera on the eyepiece
and camera power supply. The camera output format is NTSC.
|
|
|
|
6655-0009-13
|
CKM-655 - Integrated Color Camera Kit (With Monitor)
|
|
|
|
|
This kit provides a means of remotely viewing the measurement scene through the
eyepiece of the PR-655. Includes an adapter for mounting the camera on the eyepiece,
camera power supply and color monitor.
|
|
|
|
6655-0009-14
|
CC-600 - Molded Carrying Case
|
|
|
|
|
Fiberglass carrying case with molded foam inserts offering maximum protection for
the PR-655 and accessories.
|
|
|
|
6655-0009-15
|
SS-CC-600 - Soft Sided Carrying Case
|
|
|
|
|
Camera bag type with shoulder strap. Standard equipment with the PR-655.
|
|
|
|
6655-0009-16
|
TR-15 - Tripod
|
|
|
|
|
Fully adjustable tripod with SAE ¼-20 screw mount for stable measurements
with the SpectraScan when an optical table or bench is not available.
|
|
|
|
6655-0009-17
|
PR-655 Accessory Kit
|
|
|
|
|
Includes:
- CD-655 - Rapid Charger
- USB-15 - 15' USB cable
- SD - Secure Digital (SD) memory card
- SD-R - USB SD Card Reader
- BP-655 - Li-Ion Battery
|
|
|
|